Marquee 8000 Series Projector
Physical Setup:
- Position the projector:
- Connect A-C.
- Connect the RGB source (SGI's have sync on green).
- Reverse yokes to correct scan (if necessary).
- Zero the green convergence [Conv-5-0901-2-0] or initialize the projector [Util-9-0901-4].
- Set Horz. Retrace to short. [Utility-1-8]
- Optical Setup:
- Perform complete optical alignment of green CRT:
- Display internal convergence pattern [#].
- Set Contrast [Contrast] to 70%.
- Rough-in the center focus and the corner focus.
- Adjust Scheimflug bolts for best top-bottom focus (The green CRT's left-right is factory preset and rarely is wrong).
- Optimize the center and the corner focus.
- Adjust electronic focus [Pic-4]. (DO NOT do this for red or blue).
- Again optimize the center and the corner focus.
- Repeat optical focus for red and blue CRT's.
- Zero red [Conv-3-1-0] and blue [Conv-3-3-0] if projector was not initialized.
- Adjust toe-in of red and blue CRT's.
- Use converge to see alignment [Conv-3-Color].
- Adjust Zone Focus [Util-9-0901-2].
- Geometric Setup:
- Turn off red and blue CRTs [Color-2], and perform the following on green only:
- Display the Official CAVEor 'DESK (tm) Stereo Test Pattern (6" grid w/ diagonals) for all the following procedures.
- NOTICE: If you don't have it, get it or don't proceed!
- Deploy and align the "mylar grid pattern" (or install temporary center-plumb and horizontal-level lines).
- Adjust items 1 through 6 of the geometry menu.
- Adjust the projector's feet to level the center horizontal line (make it parallel to the grid's center-level line). Do this to with 1/2 scan line.
- Adjust skew [Geo-9] to plumb the vertical center line.
- If you can't get it plumb, back off from the max. adjust value by 5% and correct the remaining error later using "green move".
- Adjust H. and V. phase [Pic-1] and H. and V. size [Pic-2] until the test image fills the screen. Look to the corners!
- Verify green converge has been zeroed [Conv-5-0901-2-0].
- Check raster's vertical position on CRT face:
- Dim Contrast [Cont] to 10% .
- Look through lense for clearance above and below pattern.
- Adjust V. Phase to adjust raster position.
- Set Contrast back to 50%. (normal)
- Raise (or lower) projector feet to bring diagonals to the corners.
- Readjust V. phase.
- Readjust the projector's feet to level the center horizontal line (make it parallel to the grid's center-level line). Do this to with 1/2 scan line.
- Diagonals should intersect corners, if not, repeat geometry and phase adjustments. Note: Get this right, as phase CANNOT be used after this step.
- Setup Linearity:
- Adjust V. linearity:
- Use "C-linearity" [Geo-7] to place horizontal centerline at the desired half-height (must be a multiple of 6").
- Use "S-linearity" [Geo-8] to render the best-fit of horizontal lines to the mylar grid.
- W/o grid, make diagonals as straight as possible.
- Adjust H. linearity:
- If the vertical center line is exactly centered (equidistant left and right) and diagonals intersect the corners, skip to Step IV.
- If not , use green converge [Conv-5-0901-2] to adjust static (double zone box) position. (This will shift the whole grid, we'll fix that next).
- Superimpose the vertical center line of the CAVE test pattern on the center-plumb line. DO NOT readjust phase.
- The horizontal center line position can now be adjusted w/ C-lin... [Geo-7] accessible while still in the converge menu .
- Get this intersection 'spot on' (+/- 1/2 scan line). Geometry menu items CANNOT be adjusted after this step.
- Use green converge to adjust (re-proportion) the left half, then the right half, of the screen.
- Work each column of zones, work out from the center (this keeps overcorrecting to a minimum).
- Only do the center column if there is vestigial skew to becorrected. DO NOT readjust the center (static) zone. Again, DO NOT readjust phase.
- Make vertical-move adjustments at this time to superimpose the horiz-lines.
- Diagonals should once again intersect the four corners, if not, zero green and repeat Geometry and Linearity above.
- Anal option: If time permits, repeat all of Section IV (with out zeroing green) until optimal geometry is obtained.
- Complete Green Setup on all CAVE projectors.
- Final fitting:
- Make minor green moves to get best screen to screen continuity of CAVE(tm) Test patterns at all corners.
- Convergence:
- Converge red to green.
- Using random access, work each column of zones, work out from the center (this keeps overcorrecting to a minimum).
- Converge blue to green.
- Using random access, work each column of zones, work out from the center (this keeps overcorrecting to a minimum).
- Converge red to blue.
- Using random access, work each column of zones, work out from the center (this keeps overcorrecting to a minimum).
- Use color button to toggle to this color combo.
- Backup the completed Setup:
- Copy the completed setup to Recall #01 [Util-1-1-Recall-01-enter].
- This copies the working file to "Recall #1.
- Copy the completed setup to Recall #96 [Util-1-1-Recall-96-enter].
- This copies the working file to "Recall #96 (our backup copy).
- Recall the backup file [Recall-96].
- Lock the backup file [Util-1-3].
- Recall the working file [Recall-01].
- This leaves users with access to R #1 but keeps R #96 as an archive.
- It is advisable to "un-converge" R #96 before locking it.
- Use red converge to shift red raster left by 1/2 a test square.
- Use blue converge to shift blue raster right by 1/2 a test square.
- This will give you an indicator of tampering.